Noise Mapping in Malaysia: DOSH Colour Zones and How to Read a Noise Map

Short answer

Noise mapping shows measured noise levels on a layout plan of your workplace. Under the DOSH noise ICOP 2019 (section 7.3.2(b)), it is part of a noise risk assessment, with four colour zones: white at 82 dB(A) or below, yellow above 82 to 85 dB(A), red above 85 to 115 dB(A), and purple above 115 dB(A) or 140 dB(C).

Reviewed for accuracyLast reviewed: October 2026
Written byMuhammad Ihram ZulkefliChief Business Development and Marketing Officer, OSHMed Solutions Sdn Bhd
Reviewed byDr. Wan Muhammad Zulhusni bin Abdul HalimOccupational Health Doctor (OHD) · Offshore/Diving/Marine Medical Examiner
  • MD (NNSMA, Rus)
  • MScCH (Occ. Health, UKM)
  • MBA (ARU, UK)
  • OHD (NIOSH)
  • MRO (AOEMM)
  • TTT (HRDF)
Registrations you can verify
  • SSM 202001013523 (OSHMED Solutions Sdn Bhd)
  • DOSH registered training provider SL/22/22/181036, valid to 21 July 2028
  • MMC Full Registration 55275 (Dr. Wan Muhammad Zulhusni)
  • DOSH Occupational Health Doctor HQ/16/DOC/00/454
  • DMAC/EDTCmed 263
  • OEUK OEUK/2024/3751

OSHMed Solutions Sdn Bhd is an occupational safety and health consultancy and DOSH-registered training provider (ergonomics) in Kajang, Selangor. We are not a clinic. Medical tests are arranged through approved centres.

1-minute summary: Noise mapping: the essentials. 1) A noise map shows measured noise levels on your layout plan. 2) White: 82 dB(A) or below. Yellow: above 82 to 85 dB(A). 3) Red: above 85 to 115 dB(A). Purple: above 115 dB(A) or 140 dB(C). 4) Each machine: at least three spot readings at 1 m, then averaged. 5) The map shows where noise is; personal monitoring shows who is exposed. 6) Red and purple areas guide where hearing protection zones go. White does not mean earplugs off: the ICOP allows removal only below 80 dB(A).
1-minute summary: Noise mapping: the essentials
Key takeawaysNoise mapping: the essentials
  1. A noise map shows measured noise levels on your layout plan.
  2. White: 82 dB(A) or below. Yellow: above 82 to 85 dB(A).
  3. Red: above 85 to 115 dB(A). Purple: above 115 dB(A) or 140 dB(C).
  4. Each machine: at least three spot readings at 1 m, then averaged.
  5. The map shows where noise is; personal monitoring shows who is exposed.
  6. Red and purple areas guide where hearing protection zones go.

White does not mean earplugs off: the ICOP allows removal only below 80 dB(A).

What is noise mapping in the DOSH ICOP?

Noise mapping is an aid to visualise work locations and noise exposure levels on a general layout plan of the workplace (ICOP 2019, section 7.3.2(b)). It is part of area monitoring, one of the two parts of a noise risk assessment (7.3.1), and the registered assessor includes it in the final report.

When an NRA is required, and who may carry it out, is covered in our noise risk assessment guide.

What are the DOSH noise mapping colour zones?

Table 7.2 of the ICOP sets four colour zones by sound pressure level: white for 82 dB(A) or below, yellow for above 82 to 85 dB(A), red for above 85 to 115 dB(A), and purple for above 115 dB(A) or 140 dB(C), matching values in the Noise Exposure Regulations 2019.

Noise mapping colour zones (ICOP 2019, Table 7.2)
Colour zoneSound pressure levelWhat it signals
PurpleAbove 115 dB(A), or above 140 dB(C)Maximum and peak limits, at any moment (reg. 6(1)(b), (c)); control first
RedAbove 85 to 115 dB(A)Above the 85 dB(A) noise exposure limit value (reg. 6(1)(a)); the basis for a hearing protection zone (ICOP 11.5.1)
YellowAbove 82 to 85 dB(A)Above the 82 dB(A) excessive noise value (reg. 2), below the limit
White82 dB(A) or belowNot above the excessive noise value

The map shows spot levels. Since 82 and 85 dB(A) in the Regulations are daily exposure levels, whether a worker in a red area exceeds the limit depends on time spent there.

Printing note: Table A2 prints white as “< 82 dB(A)”; Table 7.2 prints “≤ 82 dB(A)”, matching regulation 2. The Malay Table 7.2 prints “> 140 dB(A)” for purple; the English edition uses dB(C).

How is noise mapping done?

The registered noise risk assessor measures each noise source with an integrating-averaging sound level meter, takes at least three spot readings per source and records the average (ICOP 7.3.2(a), Table 7.1). The levels are plotted on your general layout plan and coloured by Table 7.2.

  1. Instruments: meter to IEC 61672 class 1 or 2, calibrator to IEC 60942 class 1, verified within 12 months; a field calibration drift above 0.5 dB voids the results (7.2).
  2. Spot readings: 1 m from the machine and the floor level where possible, at least three per source, averaged; repeated at different times to capture variation (Table 7.1; 7.3.2(a)(iii)).
  3. Type of noise: steady (within 3 dB), fluctuating (3 to 10 dB) or impulse (Table 7.1).

The ICOP sets no grid spacing, contour method or software, only the result: a colour-zoned plan built from measurements. Any departure from the recommended sampling method must be justified in the report (7.3.2(a)(iv)).

How do you read a noise map?

Start with the legend and survey date, then follow the colours: purple and red mark levels above the limit values, yellow above the excessive noise value, white below both. Then check which workstations, walkways and break areas fall in each colour: exposure depends on where people spend their shift.

Illustrative noise map with four colour zonesOffice60 dB(A)Canteen65 dB(A)M1 · 91 dB(A)M2 · 88 dB(A)M3118 dB(A)Hearing protection zone boundaryWalkway · 83 dB(A)White: ≤ 82 dB(A)Yellow: > 82 to 85 dB(A)Red: > 85 to 115 dB(A)Purple: > 115 dB(A) or > 140 dB(C)

Illustrative noise map, not a real workplace.

Reading the illustrative map
AreaZoneWhat to check
M3, 118 dB(A)PurpleAbove the 115 dB(A) maximum (reg. 6(1)(b)): control first (ICOP 9.3.1)
M1 and M2, 88 to 91 dB(A)RedInside the hearing protection zone; protectors worn by everyone inside (reg. 8)
Walkway, 83 dB(A)YellowWho passes and how long; candidates for personal monitoring (7.3.3(f)(ii))
Office and canteen, 60 to 65 dB(A)WhiteSuitable for breaks (10.5.1); remove protectors only below 80 dB(A) (11.1.3)

How is noise mapping different from personal monitoring?

Noise mapping measures places; personal monitoring measures people. The ICOP divides a noise risk assessment into both (7.3.1). The map shows where the noise is, while a dosimeter worn for the full shift gives each exposure group its daily level and dose, which is what the noise exposure limit is checked against (7.4.2).

Noise mapping and personal monitoring compared
PointNoise mappingPersonal monitoring
InstrumentSound level meter (IEC 61672)Noise dosimeter (IEC 61252), full shift
ResultTable A1 and a colour-zoned planLEX,8h, dose, maximum and peak per SEG (Table A3)

The worker with the highest exposure in each similar exposure group (SEG) is monitored (7.3.3(b) to (f)); the calculation is in our noise dose calculator guide.

What is a noise map used for?

A noise map turns measurements into decisions: which sources to control first, where hearing protection zones go, where rest areas and workstations sit, and who needs personal monitoring. The ICOP gives priority to sources behind the highest exposures affecting the largest number of people (9.3.1).

  • Control priorities: source levels set the priority for noise control (7.3.2(a)(i)); engineering control comes first (regulation 6(4)).
  • Hearing protection zones: signposted based on noise mapping (ICOP 11.5.1); see our hearing protection zone guide.
  • Distance: noise falls by 6 dB for every doubling of distance from the source (10.3.1).
  • Quiet areas: break and meal areas must be located away from noise (10.5.1).
  • Noise control plan: required of the employer (ICOP 4.4.1(b)); DOSH’s 2024 guideline starts with the dominant source (Figure 4.1).

Need a noise map for your workplace?

Noise mapping is part of a noise risk assessment by a DOSH-registered assessor. Send your layout plan, list of noisy machines, headcount and shift hours, and OSHMed will reply with a scoped proposal: request an NRA quote.

What must the NRA report show about noise mapping?

Appendix 2 of the ICOP names noise mapping in five report sections: methodology, results, discussion, recommendations and appendices. Area monitoring results “shall be illustrated by noise mapping in the form of colour zone”, and the layout plan and map are attached. Check them before you confirm Form A.

Where noise mapping appears in the NRA report (ICOP Appendix 2)
Report sectionWhat it must contain
(e) MethodologyNoise sources, sampling method, noise mapping (zoning), type of noise
(f) ResultTable A1 of area monitoring and the colour-zone map
(g) DiscussionExisting controls and a comment on the noise mapping
(h) RecommendationsControls per SEG (Table A4) and areas to be signposted as hearing protection zones
(k) AppendixLayout plan for machinery and employees, noise mapping, data sheets, calibration certificate

The report is due within one month of the assessment (regulation 4(4)). The rest is in our NRA guide; fees are in our NRA cost guide.

What should you prepare before noise mapping?

Prepare a layout plan, a list of every machine, your shift and break pattern, headcount by area and job, and your last identification and NRA. The assessor needs them to plan measuring points, define exposure groups and draw the map on an accurate plan. Use the checklist below to see what you already have.

Free tool

Ready for noise mapping? What the assessor needs from you

Tick each item you can hand to the noise risk assessor before the site visit. The 12 items follow what the ICOP asks the assessor to measure, record and attach to the report (section 7.3 and Appendix 2). Print the list for your team, or send your score to OSHMed on WhatsApp.

0 of 12 ready

Not ready yet. Start with items 1, 2 and 5: without a layout plan, a machine list and shift times, the assessor cannot plan where to measure. If you have no written identification, our noise identification checklist guide comes first.
Nearly ready. Fill the gaps before the visit so that the map and the exposure groups match how your site really runs. Send this result to OSHMed for a scoped noise risk assessment.
Ready for noise mapping. Share the documents with the assessor before the visit and agree on a date when all machines run normally. See our NRA service or request a quote.
Send my result to OSHMed on WhatsApp

OSHMED Solutions Sdn Bhd, based in Kajang, Selangor, serves employers across Malaysia and quotes in writing. Through our noise risk assessment service, the assessment is carried out by a DOSH-registered noise risk assessor, as the law requires, and ends with a written report. Every report names the responsible registered assessor and their myKKP registration number, so you can verify it on the DOSH register.

Ask for an NRA quote now if:
  • You have no noise map, or the last one predates a change in machines or layout.
  • Your excessive noise identification found an area that may exceed 82 dB(A).
  • Your last NRA is nearly five years old, or missing.

Before you decide: three common objections

Three objections come up when employers plan noise mapping: using their own meter, assuming a yellow area is safe, and keeping an old map after a layout change. Each is checked below against the Noise Exposure Regulations 2019 and the ICOP.

"We can draw the noise map ourselves."

Useful for planning, but the NRA map is the registered assessor’s work, with IEC-compliant instruments (regulation 4; ICOP 7.2.2).

"Our area is yellow, so it is safe."

Yellow is above the 82 dB(A) excessive noise value, and shift length matters: 84 dB(A) for 12 hours gives a daily level of 85.8 dB(A), above the limit (regulation 6(1)(a)).

"We moved two machines, but the old map is fine."

Regulation 3(2)(a) requires re-identification after changes in machinery or process; the NRA is reviewed within five years (regulation 4(8)).

Frequently asked questions

What is noise mapping?

A workplace plan showing measured noise levels in colour zones; under the DOSH ICOP (2019, section 7.3.2(b)), part of area monitoring in a noise risk assessment.

What do the colours on a DOSH noise map mean?

White: 82 dB(A) or below. Yellow: above 82 to 85 dB(A). Red: above 85 to 115 dB(A). Purple: above 115 dB(A) or above 140 dB(C) (ICOP Table 7.2).

Is noise mapping required in Malaysia?

It is part of the noise risk assessment required by regulation 4 once excessive noise is identified, and ICOP Appendix 2 says area monitoring results shall be illustrated by a colour-zone map. The ICOP is issued under section 37 of Act 514 and is admissible in evidence (section 38).

Can noise mapping software replace measurements?

Not for the NRA of an existing workplace: the ICOP map is built from the assessor’s spot measurements (7.3.2(b)). DOSH’s 2024 noise control guideline mentions predictive modelling software for planning new plant (section 4.5).

Does a white zone mean workers can remove hearing protectors?

Not by itself. White covers up to 82 dB(A), but protectors, if removed, shall be removed in areas below 80 dB(A) (ICOP 11.1.3).

Your next step

Tick the checklist above, gather what is missing, then request an NRA quote or send your result on WhatsApp.

Already have red or purple areas? Mark the hearing protection zones, plan the hearing conservation programme and our yearly hearing conservation training (training page). Other workplace assessments are on one page.

Get your noise map through a registered NRA

Share your readiness checklist result on WhatsApp or through the quote form. We will tell you what the assessor needs from you before the site visit.

Sources and references

Disclaimer: This article is general information for employers and is not legal advice. Requirements depend on your workplace, processes and the current law. For a decision on your premises, speak to a DOSH-registered competent person or contact DOSH (JKKP).